- Australia
KingZip Standing Seam
Surespec | : |
0421a-Roofing - rainwater systems
0471-Thermal insulation and pliable membranes
0423-Roofing – Profiled Sheet Metal
|
Speedspec | : |
07200-Thermal & Acoustic Insulation
07610-Roofing and Roof Plumbing
|
Application | : | All roofing applications where the installed roof pitch is 1.5º or greater | Used as a vertically laid wall cladding solution |
Colour | : | Grey |
Finishes | : | Mill finish or plain stucco embossed finish | PVDF and Kingspan Polyester | Colorbond standard, ultra and matt |
Installation | : | Exterior |
Material | : | Aluminium | Steel |
Material detail | : | Aluminium: 0.90 mm or 1.20 mm | Steel: 0.55 mm or 0.75 mm (COLORBOND Steel), Aluminium: 0.90 or 1.20 mm | Steel: 0.55 or 0.75 mm (COLORBOND Steel) |
Type | : | Standing seam |
Usage | : | Roofing |
Cover width | : | 300 mm | 400 mm | ± 2 mm |
Edge squareness | : | 1 % of sheet cover width |
Nominal thickness | : | 0.90 mm , 1.20 mm (aluminium) | 0.75 mm (Colorbond Steel), 0.90 mm | 1.20 mm (aluminium) | 0.75 mm (Colorbond Steel) |
Over 10 m long | : | +10 mm (+1 mm per metre length over 10 m) / -5 mm |
Profile depth | : | 65 mm |
Sheet length | : | 1.5 mm to 15 mm (factory rolled – due to transport limitation) | 1.5 mm to 150 mm (site rolled) |
Sheet width | : | 300 mm and 400 mm standard pan widths | 400 mm is most economical | Custom pan widths available from 200 mm - 400 mm |
Up to 10 m long | : | +10 mm / -5 mm |
Can be tapered | : | Yes |
Drumming | : | BS 5427: 2016+A1: 2017 states that this noise can be reduced by the introduction of a flexible insulation layer directly under the outer sheets |
End Laps | : | For a pitch greater than 3° the overlap joint must be fixed with end lap rivets (6604/6/3W) | Sealed with end lap sealant (TAPE/BM/06) |
Finishes and coating | : | The external weather sheet is available in either Colorbond Steel or aluminium in a variety of finishes including; mill finish or plain stucco embossed finish, and PVDF coatings |
Fire performance | : | Deemed to Satisfy (DTS) non-combustible under provision C1.9 (e)(v) of the National Construction Code |
Lightning Protection | : | Requirements of BS EN/IEC 62305 | Roof systems combined with the steel frame of the building can be used to provide a principal lightning protection system |
Reaction to fire | : | Combustibility test for materials: AS 1530.1: 1994 (2016) | Ignitability Index: 0 | Spread of Flame Index: 0 | Heat Evolved Index: 0 | Smoke Developed Index: 1 - 2 |
Suitable for curved applications | : | Can be curved to 5 m for convex and 8 m for concave (For 0.9 mm thick aluminium) |